Pubblicazioni

Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen  (2010)

Autori:
Gallotti, A; D'Onofrio, Mirko; POZZI MUCELLI, Roberto
Titolo:
Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen
Anno:
2010
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Italiano
Formato:
A Stampa
Referee:
Nome rivista:
Radiologia Medica
ISSN Rivista:
0033-8362
N° Volume:
115
Numero o Fascicolo:
6
Intervallo pagine:
889-897
Parole chiave:
ARFI ultrasound imaging; Virtual Touch tissue quantification; Healthy abdominal organs
Breve descrizione dei contenuti:
PURPOSE: Virtual Touch tissue quantification is an implementation of ultrasound (US) Acoustic Radiation Force Impulse (ARFI) imaging that provides numerical measurements (wave-velocity values) of tissue stiffness. The aim of this study was to define the normal values of shear-wave speed for the healthy liver, gallbladder, pancreas, spleen and kidneys. MATERIALS AND METHODS: Thirty-five young healthy volunteers underwent Virtual Touch tissue quantification after having signed an informed consent form. All upper abdominal organs were examined by two independent operators. A phantom fluid model was also evaluated. All mean wave-velocity values were analysed and compared. RESULTS: One hundred and forty measurements of liver, pancreas, spleen and kidneys, and 70 measurements of the gallbladder lumen were performed. Twenty measurements on the phantom were also performed. Comparing all measurements separately made by each operator in different parts of the organs, no statistically significant differences were observed. A "XXXX/0" value was always obtained from all measurements performed on the gallbladder lumen and on the phantom fluid model. Liver, pancreas, spleen and kidney mean values were 1.59 m/s, 1.40 m/s, 2.44 m/s and 2.24 m/s, respectively. CONCLUSIONS: Virtual Touch tissue quantification is a new, promising implementation of the US ARFI technique, which provides numerical measurements of tissue stiffness. The mean shear-wave speed is lower in the pancreatic parenchyma than in the liver and kidney, whereas the spleen is characterised by the highest mean value. In simple fluids such as water, the value identified by the system with "XXXX" or 0, is always measured
Id prodotto:
53674
Handle IRIS:
11562/339497
depositato il:
22 gennaio 2010
ultima modifica:
15 novembre 2022
Citazione bibliografica:
Gallotti, A; D'Onofrio, Mirko; POZZI MUCELLI, Roberto, Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen «Radiologia Medica» , vol. 115 , n. 62010pp. 889-897

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<indietro

Attività

Strutture

Condividi