Pubblicazioni

Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis  (2013)

Autori:
Marcela Nogueira Rabelo, Alves; Gabriele, Zanchetti; Alberto, Piccinotti; Silvia, Tameni; Bruno Spinosa De, Martinis; Polettini, ALDO ELIANO
Titolo:
Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis
Anno:
2013
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Inglese
Formato:
A Stampa
Referee:
Nome rivista:
Analytical and Bioanalytical Chemistry
ISSN Rivista:
1618-2642
N° Volume:
405
Numero o Fascicolo:
19
Editore:
Springer Verlag
Intervallo pagine:
6299-6306
Parole chiave:
cocaine; hair; analysis; column switching; liquid chromatography; mass spectrometry
Breve descrizione dei contenuti:
A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography-tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source.
Id prodotto:
85523
Handle IRIS:
11562/881390
depositato il:
30 gennaio 2015
ultima modifica:
2 dicembre 2022
Citazione bibliografica:
Marcela Nogueira Rabelo, Alves; Gabriele, Zanchetti; Alberto, Piccinotti; Silvia, Tameni; Bruno Spinosa De, Martinis; Polettini, ALDO ELIANO, Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis «Analytical and Bioanalytical Chemistry» , vol. 405 , n. 192013pp. 6299-6306

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<indietro

Attività

Strutture

Condividi