Concentration of ethylene oxide in the alveolar air of occupationally exposed workers
Year:
1985
Type of item:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Language:
Inglese
Format:
A Stampa
Referee:
Sì
Name of journal:
American Journal of Industrial Medicine
ISSN of journal:
0271-3586
N° Volume:
8
Page numbers:
67-72
Keyword:
Ethylene oxide - alveolar air - hospital sterilizer -
Short description of contents:
Ethylene oxide was tested in environmental air and in the alveolar air of 10 workers employed in a hospital sterilizer unit at hourly intervals during the work shift. Alveolar ethylene oxide concentrations (Ca) were correlated with environmental concentration (Ci) in all the workers studied (r = 0.89-0.99). The ratio between alveolar and environmental concentration (Ca/Ci) given by the slope of the regression line obtained for all the data collected was 0.24. This means that the alveolar retention of ethylene oxide, expressed as 1 - (Ca/Ci), corresponded, on average, to about 75% of the environmental concentration.
Product ID:
3953
Handle IRIS:
11562/3953
Deposited On:
July 5, 2012
Last Modified:
June 28, 2015
Bibliographic citation:
F. Brugnone; L. Perbellini; G. Faccini; F. Pasini,
Concentration of ethylene oxide in the alveolar air of occupationally exposed workers«American Journal of Industrial Medicine»
, vol. 8
, 1985