- Authors:
-
Marcela Nogueira Rabelo, Alves; Gabriele, Zanchetti; Alberto, Piccinotti; Silvia, Tameni; Bruno Spinosa De, Martinis; Polettini, ALDO ELIANO
- Title:
-
Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis
- Year:
-
2013
- Type of item:
-
Articolo in Rivista
- Tipologia ANVUR:
- Articolo su rivista
- Language:
-
Inglese
- Format:
-
A Stampa
- Referee:
-
Sì
- Name of journal:
- Analytical and Bioanalytical Chemistry
- ISSN of journal:
- 1618-2642
- N° Volume:
-
405
- Number or Folder:
-
19
- :
- Springer Verlag
- Page numbers:
-
6299-6306
- Keyword:
-
cocaine; hair; analysis; column switching; liquid chromatography; mass spectrometry
- Short description of contents:
- A method for rapid, selective, and robust determination of cocaine (CO) and metabolites in 5-mg hair samples was developed and fully validated using a column-switching liquid chromatography-tandem mass spectrometry system (LC-MS-MS). Hair samples were decontaminated, segmented, incubated overnight in diluted HCl, and centrifuged, and the diluted (1:10 with distilled water) extracts were analyzed in positive ionization mode monitoring two reactions per analyte. Quantifier transitions were: m/z 304.2→182.2 for CO, m/z 290.1→168.1 for benzoylecgonine (BE), and m/z 318.2→196.2 for cocaethylene (CE). The lower limit of quantification (LLOQ) was set at 0.05 ng/mg for CO and CE, and 0.012 ng/mg for BE. Imprecision and inaccuracy at LLOQ were lower than 20 % for all analytes. Linearity ranged between 0.05 and 50.0 ng/mg for CO and CE and 0.012 and 12.50 ng/mg for BE. Selectivity, matrix effect, process efficiency, recovery, carryover, cross talk, and autosampler stability were also evaluated during validation. Eighteen real hair samples and five samples from a commercial proficiency testing program were comparatively examined with the proposed multidimensional chromatography coupled with tandem mass spectrometry procedure and our reference gas chromatography coupled to mass spectrometry (GC-MS) method. Compared with our reference GC-MS method, column-switching technique and the high sensitivity of the tandem mass spectrometry detection system allowed to significantly reduce sample amount (×10) with increased sensitivity (×2) and sample throughput (×4), to simplify sample preparation, and to avoid that interfering compounds and ions impaired the ionization and detection of the analytes and deteriorate the performance of the ion source.
- Product ID:
-
85523
- Handle IRIS:
-
11562/881390
- Deposited On:
-
January 30, 2015
- Last Modified:
-
December 2, 2022
- Bibliographic citation:
-
Marcela Nogueira Rabelo, Alves; Gabriele, Zanchetti; Alberto, Piccinotti; Silvia, Tameni; Bruno Spinosa De, Martinis; Polettini, ALDO ELIANO,
Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis
«Analytical and Bioanalytical Chemistry»
, vol.
405
, n.
19
,
2013
,
pp. 6299-6306
Consulta la scheda completa presente nel
repository istituzionale della Ricerca di Ateneo